12005A KDONAr-1600-50Y/1200/35Y Gas Oxygen/Gas Nitrogen/Liquid Argon Cryogenic Air Separation Plant
Tag No.: 12005A
Model: KDONAr-1600-50Y/1200/35Y
Name: Gas Oxygen/Gas Nitrogen/Liquid Argon Cryogenic Air Separation Plant
Product parameters:
Describe |
Yield |
Purity |
Out of cold box pressure |
Gas oxygen |
1600 Nm³/hr (2000Kg/hr) |
99.6% O2 |
0.02MPa G |
Liquid oxygen |
50 Nm³/hr (71Kg/hr, 62L/hr) |
0.1MPa G |
|
Gas Nitrogen |
1200 Nm³/hr (1500Kg/hr) |
100ppmO2 |
0.01MPa G |
Liquid argon |
35 Nm³/hr (62Kg/hr, 43.5L/hr) |
100ppmO2 |
0.1MPa G |
Installed power: ~1573KW
Shaft power consumption: ~1189KW
Circulating cooling water volume: ~150m³/hr
Equipment introduction:
This air separation equipment can produce atmospheric oxygen, gas nitrogen, and liquid argon at the same time, and can produce a small amount of liquid oxygen and liquid nitrogen for standby. It can be used in the metallurgical industry, steelmaking industry and other production processes that require oxygen, nitrogen, and argon. Used for on-site pipeline gas supply. Due to the low pressure of oxygen and nitrogen, it is usually necessary to configure externally compressed piston oxygen compressors and nitrogen compressors to pressurize to a certain pressure to the gas storage tank, and then decompress from the gas storage tank to supply the owner's other oxygen and other needs through pipelines. Production process of nitrogen and argon.
In terms of process, the classic two-tower process is used to produce high-purity oxygen and high-purity nitrogen at the same time, starting from the air compressor, all low-pressure working processes. The system is mainly composed of oil-free centrifugal air compressors, air pre-coolers, and air purifiers ( It is composed of activated alumina and 13X APG molecular sieve), air separation cold box (using aluminum plate-fin heat exchanger, aluminum sieve plate rectification tower and aluminum structured packing tower), turbo expander and other monomer equipment. The gas pressurization of the rear product needs to be equipped with a piston oxygen compressor, a nitrogen compressor, an intake buffer tank, an exhaust gas storage tank, a pressure reducing device, etc. The back-end liquid storage backup system needs to be equipped with liquid oxygen storage tanks, liquid nitrogen storage tanks, liquid oxygen pumps, liquid nitrogen pumps, vaporizers, etc.
The whole system is controlled by Siemens PLC. The main pressure, temperature, flow, differential pressure and other data are displayed and stored in the PLC through signal transmission. The main operating valves are pneumatic valves, and the logic interlocking operation and control are completed in the PLC.
For more details, please feel free to contact us by email to sales@wintekgroup.com
Key Words: Gas Oxygen Cryogenic Air Separation Plant, Gas Nitrogen Cryogenic Air Separation Plant, Liquid Argon Cryogenic Air Separation Plant
Product Center
Request for Quotation
CONTACT INFORMATION
Mobile: +86 18936090872
Tel: +86 512 69552989
Email: sales@wintekgroup.com
Skype ID: rongqiang.wang
Telegram/Whatsapp/Wechat ID:+86 18936090872
OFFICIAL WECHAT
QUICK LINKS
- Homepage
- about us
- Hardware Display
- software display
- development process