Home    58000 Series-Cryogenic Liquid Pump    58203A SLP-18/280 LNG Submersible Pump

58203A SLP-18/280 LNG Submersible Pump

Tag No.58203A

ModelSLP-18/280

NameLNG Submersible Pump

 

1. Technical specifications

SN

Name

Specifications

Note

1

Model

SLP-18/280

 

2

Type

Vertical, single suction, two-stage, direct connected submerged centrifugal pump

 

3

Medium

LNG/LN2

 

4

Medium density

425kg/m³

 

5

Medium temperature

≤-135

 

6

Design temperature

-196ºC

 

7

Design flow

20 m³/h(liquid)

 

8

Design head

300m

 

9

Design speed

6000r/min

 

10

Allowable speed

≤6000r/min

The lower the speed, the better

11

Minimum flow

6.5m³/h(liquid)

 

12

Cavitation allowance NPSHr

1.5m

Design condition

13

Inlet pressure (gauge pressure)

0.021.2MPa

 

14

Variable frequency motor power/number of poles/speed

15KW/2P/6000r/min

 

15

Efficiency of variable frequency motor

0.86

 

16

Power factor of variable frequency motor

0.91

 

17

Insulation grade of variable frequency motor

F

 

18

Frequency conversion range

0-100hz (constant torque)

100-105hz (constant power)

 

19

Flow range

5-25 m³/ h (liquid)

 

20

Head range

120-300m

 

21

Net weight

≈ 88Kg

 

22

Noise

≤75dB

Measured at 1m around

 

2. Design standard

SN

Standard Code

Standard Name

1

GB/T 1176-2013

Cast copper and copper alloys

2

GB/T 1220-2007

Stainless steel rod

3

API610-2004

Centrifugal pumps for the oil, heavy chemical and gas industries

4

GB/T5656-2008

Technical Conditions of Centrifugal Pumps ()

5

GB/T 22724

LNG equipment and installation onshore design

6

GB/T 19204

General characteristics of LNG

7

JB/T6879-2008

Dimensional tolerance of centrifugal pump casting over-current part

8

ISO1940-2003

Mechanical Vibration Balance Quality Requirements for Rigid Rotors

9

GB/T 3216-2005

Acceptance test of hydraulic performance of rotary power pump

10

JB/T8098-1999

Pump noise measurement and evaluation method

11

GB/T13007-2011

centrifugal pump efficiency

12

CCS

Specification for construction and equipment of ships carrying liquefied gases in bulk

13

CCS

Specification for natural gas fueled ships

14

GB 755-2008

Rotating Electric Machine Ratings and Performance

15

GB 1032-1990

Three-phase asynchronous motor test method

16

GB 1971-1980

Motor wire end marking and direction of rotation

17

GB 14711-1992

General requirements for the safety of small and medium rotating electrical machines

18

GB 191-1990

Packaging, storage and transportation icons

19

ASTM B62-09

Standard specification for Composition Bronze or Ounce Metal Castings

20

ASTM A351/A351: 2000

Austenitic, austenitic-ferritic (duplex) steel castings for pressure components

21

ISO1940:2003

Mechanical vibration-Balance quality requirements for rotor in a constant (rigid) state

 

Product introduction:

Purpose: to transfer LNG from storage tank, pressurize and fill the vehicle with LNG.

Transmission medium: LNG.

Structure: vertical, single suction, two-stage, direct connected submersible centrifugal pump. The pump is coaxial with the motor. The axial force is balanced by adjusting the impeller nozzle ring, and the radial force is balanced by multi-channel guide vane design. The residual axial force and radial force are borne by low-temperature bearing. When the operation and medium temperature change, the rotor can float up and down freely, and the deformation of the disc spring produces different supporting forces to support the rotor.

Bearing: imported customized low-temperature bearing, which balances part of the axial force through the balance hole, and the remaining axial force is borne by the motor bearing. The bearing adopts medium self-lubrication.

The submersible pump is connected with the upper cover of the pump pool through four M10 bolts, and the low-temperature outgoing cable is connected through a special cable connector.

Driving mode/transmission direction: motor driven, counterclockwise rotation from the driving end (judge whether the motor direction is correct through the outlet pressure during the initial operation).

Foundation form: pump sump base, 4pc of φ24 holes.

The performance curve is gentle.

The critical speed of the pump shall not be lower than 125% of the rated speed.

The trouble-free operation time of the pump set is 10000 hours.

The installation and interface dimensions of the same model of cryogenic centrifugal pump shall be completely consistent and interchangeable.

All rotating parts shall be assembled together for dynamic balance test. According to ISO1940:2003 standard, the balance accuracy reaches G2 Level 5.

 

For more information, please contact us by email sales@wintekgroup.com .

 

Key Words: LNG Submerged Pump, Centrifugal Liquid Pump, LNG Filling Pump, LNG Filling Station Pump

 
 
58200 Series-Centrifugal Cryogenic Liquid Pump

Request for Quotation

Name *

Mobile phone

E-mail *

Company *

Message *