1.Technical parameter of the Unit

SN

Name

Parameter

1.1

Model

BGYL050F/44Y

1.1

Natural gas processing capacity

900 Kg/h

876.1 Kg/h

876 Kg/h

1.3

Inlet temperature

60

53

66

1.4

Natural gas inlet pressure

4.41 MPa G

4.2 MPa G

0.03 MPa G

1.5

Cooling method

Air cooling

1.6

Power

400 V/50 HZ

1.7

Work mode

Continuous work

1.8

Natural gas outlet temperature

40

40

40

1.9

Rated cooling capacity

52 KW

1.10

Shaft power

20 KW

1.11

Rated power

30 KW

1.12

Operating current

33 A

1.13

Minimum distribution power

30 KW

1.14

Energy regulation

33% to 100% infinitely adjustable

1.15

Diameter of natural gas connection pipe

DN50

1.16

Pressure loss

≤(10 KPa

1.17

Refrigerant

R134A

1.18

Cooling method

Air cooling

1.19

Structure

Copper sleeve aluminum fin

1.20

Ambient temperature

42

1.21

Number of blowers

2 sets

1.22

Single blower air capacity

15000 m3/h

1.23

Single blower power

1.1 KW

1.24

Protection grade of motor

Exhd BT4

1.25

Equipment installation location

Indoor

N1

Remark

N1.1

The cooling capacity refers to the cooling capacity of compressed natural gas under standard conditions of inlet and outlet, with an ambient temperature of 42.

 