Home    53000 Series-Gas Blower    53100 Series-Roots Blower    53102A TZR8-750NJS3(ZR8-750NJS3+ZR7-750NJS3) Blower

53102A TZR8-750NJS3(ZR8-750NJS3+ZR7-750NJS3) Blower

Tag No.: 53102A

Model: TZR8-750NJS3(ZR8-750NJS3+ZR7-750NJS3)

Name: Blower

 

1st stage compressor:

Inlet pressure: 25~35KPa G;

Inlet temperature : 50~60℃ ;

Inlet flow: 110000Nm³/h;

Outlet pressure: 110~130KPa G

Average molecular weight of conveying medium: 18.196

Transmission medium adiabatic index k: 1.358

 

Model selection proposal:

Name

Data

Blower model

TZR8-750NJS3 (ZR8-750NJS3+ZR7-750NJS3)

Local atmospheric pressure Po (kPa ABS)

100

Inlet pressure Ps (KPa G)

25

Discharge pressure Pd (KPa G)

120

Blower inlet temperature ts (℃)

60

Blower speed (r/min)

590

Blower boost (KPa)

95

Blower shaft power (KW)

1650

Exhaust temperature of 1st stage blower (°C)

95(The outlet pressure of the 1st stage blower is about 170kPa ABS)

Secondary blower exhaust temperature (°C)

80

Blower inlet flow rate (m³/min)

920 (55600Nm³/h)

Blower inlet flange diameter (mm)

800

Blower outlet flange diameter (mm)

700

Motor (number of poles, power)

10-pole 1800kW double-shaft extension explosion-proof motor

Remark

Two TZR8-750NJS3 blowers meet the user's requirements with a flow rate of 11000Nm³/h; the flow parts of the blowers are made of 304 stainless steels; the mechanical seal uses demineralized water as the flushing fluid; the first blower ZR8-750NJS3, the secondary ZR7-750NJS3; ≤ 45 °C

Note : Calculation and selection based on the inlet temperature of 70℃, inlet pressure of 110kPa G, boost pressure of 90kPa, and local atmospheric pressure of 100kPa.

 

For more information, please contact us by email sales@wintekgroup.com 

 

Key Words: Blower, Roots Blower, Motor

53100 Series-Roots Blower