53102A TZR8-750NJS3(ZR8-750NJS3+ZR7-750NJS3) Blower
Tag No.: 53102A
Model: TZR8-750NJS3(ZR8-750NJS3+ZR7-750NJS3)
Name: Blower
1st stage compressor:
Inlet pressure: 25~35KPa G;
Inlet temperature : 50~60℃ ;
Inlet flow: 110000Nm³/h;
Outlet pressure: 110~130KPa G
Average molecular weight of conveying medium: 18.196
Transmission medium adiabatic index k: 1.358
Model selection proposal:
Name |
Data |
Blower model |
TZR8-750NJS3 (ZR8-750NJS3+ZR7-750NJS3) |
Local atmospheric pressure Po (kPa ABS) |
100 |
Inlet pressure Ps (KPa G) |
25 |
Discharge pressure Pd (KPa G) |
120 |
Blower inlet temperature ts (℃) |
60 |
Blower speed (r/min) |
590 |
Blower boost (KPa) |
95 |
Blower shaft power (KW) |
1650 |
Exhaust temperature of 1st stage blower (°C) |
95(The outlet pressure of the 1st stage blower is about 170kPa ABS) |
Secondary blower exhaust temperature (°C) |
80 |
Blower inlet flow rate (m³/min) |
920 (55600Nm³/h) |
Blower inlet flange diameter (mm) |
800 |
Blower outlet flange diameter (mm) |
700 |
Motor (number of poles, power) |
10-pole 1800kW double-shaft extension explosion-proof motor |
Remark |
Two TZR8-750NJS3 blowers meet the user's requirements with a flow rate of 11000Nm³/h; the flow parts of the blowers are made of 304 stainless steels; the mechanical seal uses demineralized water as the flushing fluid; the first blower ZR8-750NJS3, the secondary ZR7-750NJS3; ≤ 45 °C |
Note : Calculation and selection based on the inlet temperature of 70℃, inlet pressure of 110kPa G, boost pressure of 90kPa, and local atmospheric pressure of 100kPa.
For more information, please contact us by email sales@wintekgroup.com
Key Words: Blower, Roots Blower, Motor
Product Center
Request for Quotation
CONTACT INFORMATION
Mobile: +86 18936090872
Tel: +86 512 69552989
Email: sales@wintekgroup.com
Skype ID: rongqiang.wang
Telegram/Whatsapp/Wechat ID:+86 18936090872
OFFICIAL WECHAT
QUICK LINKS
- Homepage
- about us
- Hardware Display
- software display
- development process