53103A TZR8-850NJS3(ZR8-850NJS3+ZR8-700NJS3) Blower
Tag No.:53103A
Model:TZR8-850NJS3(ZR8-850NJS3+ZR8-700NJS3)
Name:Blower
Secondary compressor:
Inlet pressure: 110~130KPa G;
Inlet temperature : 60~70℃;
Inlet flow: 110000Nm³/h;
Outlet pressure: 200~220KPa G
Average molecular weight of conveying medium: 18.196
Transmission medium adiabatic index K: 1.358
Model selection proposal:
Name |
Data |
Blower model |
TZR8-850NJS3 (ZR8-850NJS3+ZR8-700NJS3) |
Local atmospheric pressure Po (KPa ABS) |
100 |
Inlet pressure Ps (KPa G) |
110 |
Discharge pressure Pd (KPa G) |
200 |
Blower inlet temperature ts (℃) |
70 |
Blower speed (r/min) |
590 |
Blower boost (KPa) |
90 |
Blower shaft power (KW) |
1980 |
Exhaust temperature of primary blower (°C) |
95 (the outlet pressure of the primary blower is about 262kPa ABS) |
Secondary blower exhaust temperature (°C) |
62 |
Blower inlet flow rate (m³/min) |
1120(114000Nm³/h) |
Blower inlet flange diameter (mm) |
900 |
Blower outlet flange diameter (mm) |
700 |
Motor (number of poles, power) |
10-pole 2200kW double-shaft extension explosion-proof motor |
Remark |
The flow rate of 1 blower is 110000Nm³/h ; the flow parts of the blower are made of 304 stainless steel, and the mechanical seal uses demineralized water as the flushing fluid; the first-stage blower is ZR8-850NJS3, the second -stage blower is ZR8-700NJS3; the inlet gas temperature of the second-stage blower is ≤ 45 ℃ |
Note : Calculation and selection based on the inlet temperature of 70℃, inlet pressure of 110kPa G, boost pressure of 90kPa, and local atmospheric pressure of 100kPa
For more information, please contact us by email sales@wintekgroup.com
Key Words: Blower, Roots Blower
Product Center
Request for Quotation
CONTACT INFORMATION
Mobile: +86 18936090872
Tel: +86 512 69552989
Email: sales@wintekgroup.com
Skype ID: rongqiang.wang
Telegram/Whatsapp/Wechat ID:+86 18936090872
OFFICIAL WECHAT
QUICK LINKS
- Homepage
- about us
- Hardware Display
- software display
- development process